The integration of vortex flowmeter

5一體化渦街流量計02.png
5一體化渦街流量計01.png
  • 5一體化渦街流量計02.png
  • 5一體化渦街流量計01.png
Integration of vortex flowmeter is mainly used for industrial piping medium fluid flow measurement, …

Description:

Products overview:
ZW - LUGB seriesThe integration of vortex flowmeterIs widely used in the world of gas flow metering instrument, because the instrument has some other incomparable advantages of the flow meter, meter constant stable for a long time, through the piezoelectric probe can measure frequency of vortex separation, on the basis of frequency reflects the flow, can output pulse signal or frequency standard (4 ~ 20 mA current signal, match with corresponding industrial automation instrument, it can display instantaneous and cumulative flow, realize many functions such as flow measurement and automatic control, high reliability, almost no maintenance.Is widely seen as dominant in the future flow meter, orifice flowmeter is the ideal alternative products.Mainly used in petroleum, chemical industry, metallurgy, electricity, heating and other industries and municipal construction, environmental protection engineering in a variety of liquids, gases and steam flow measurement and control.

Second, the working principle:
ZW - LUGB series vortex flowmeter are integrated in the measuring tube vertically inserted a pillars, the fluid through the pillars on both sides is alternately with the rules of the vortex, the spiral column is called the karman vortex street.The release of the karman vortex street frequency is related to the width of the fluid velocity and pillars, expressed by the type:
f=St·v/d 
Type: - the release of the karman vortex street frequency f
St - coefficient (called, ha)
V - velocity
D - the width of the pillars
Karman vortex street release frequency f and is directly proportional to the velocity v, so by measuring the karman vortex street release frequency to calculate the instantaneous flow rate.
Stern lo ha is one of the important coefficient of vortex flowmeter.In its number of St 0.17 straight part of the material, the release of the vortex frequency is proportional to the velocity of flow, so check out the velocity v, frequency f can be obtained to calculate volume flow by v.
Vortex flow sensor be vortex frequency is applied to detect sensor by vortex alternately (probe) on in-situ stress in its internal piezoelectric element to check out.
Applications:
ZW - LUGB seriesIntegration of vortex flowmeters are widely used in petroleum, chemical industry, metallurgy, machinery, paper, and the city pipe heating, water supply, gas and other industries of all kinds of low viscosity liquid, gas, steam, etc of single-phase fluid process measurement and energy saving management。

Four, the main features:
1, the advantage is ant-vibration performance is very good, no zero drift, high reliability.
2, sensors, versatility is very strong, so that the sensor has good compatibility with advanced CNC processing equipment sensor table body and spiral body, etc., to ensure the machining accuracy, so that the parts (especially spiral body) versatility, thus truly will not affect by parts to replace the repeatability and precision of the sensor;Can produce a strong and stable vortex signal.
3, in a certain range of Reynolds number, flow characteristic from the fluid pressure, the influence of the temperature, viscosity, density, composition, is only involved in the body shape and size of the vortex.
4, output is proportional to the flow of the pulse signal or analog signal, no zero drift, high precision, convenient and computer connected to the Internet.
5, simple structure, no moving parts, high reliability, convenient in operation and maintenance.
6, detecting element, not contact with the media, stable performance and long service life, sensor detection probe with spiral body separate installation, and high temperature piezoelectric crystal seal in detecting probe, not contact with the measured medium, so vortex flowmeter has the characteristics of simple structure, high universality and high stability.
7, wide measuring range, range than can reach 1:10.
8, measure the volume flow without compensation, when the vortex of the output signal is actually with a linear relationship with velocity, namely is proportional to the volume flow.The purpose of the pressure and temperature compensation is to get the fluid density, multiply by volume flow to mass flow, if the measurement of the volume of a gas flow would be no need for compensation.
Five, the technical parameters:
1, the measured medium: gas, liquid and vapor;
2, connection mode: flange card mounted, flange, plug-in;
3, diameter specifications flange mounted caliber select 25,32,50,80,100;
4, the flange connection type choose 100150200;
5, flow range (see chart flow range)
6, normal measuring velocity range Reynolds number 104 ~ 1.5 x 4 x 106;Gas 5 to 50 m/s;Liquid 0.5 ~ 7 m/s;
7, measurement accuracy 1.0 magnitude 1.5 on the Richter scale;
8, measured medium temperature: room temperature - 25 ℃ ~ 100 ℃, high temperature - 25 ℃ ~ 150 ℃ to 25 ℃ ~ 250 ℃;
9, high output signal pulse voltage output signal level 8 ~ 10 V low level from 0.7 V to 1.3 V;
10, pulse duty ratio is about 50%, transmission distance is 100 m;
11, pulse current 4 ~ 20 mA remote transmission signal, transmission distance is 1000 m;
12, instrument: using the environment temperature 25 ℃ ~ + 55 ℃, humidity: 5 ~ 90% RH50 ℃;
13, the material of stainless steel, aluminum alloy;
14, DC24V power supply or lithium battery 3.6 V;
15, explosion-proof grade this Ann model iaIIbT3 - T6, protective class IP65.

Six, appearance size:

DN

A

B

C

D

15

90

Φ 57

383

45

20

100

Φ 57

388

50

25

100

Φ 57

394

50

32

100

Φ 65

396

50

40

100

Φ 75

401

50

50

110

Φ 87

407

55

65

110

Φ 109

418

55

80

110

Φ 120

423

55

100

120

Φ 149

447

60

125

125

Φ 175

474

65

150

145

Φ 203

501

75

200

170

Φ 259

556

100

250

190

Φ 312

608

120

300

210

Φ 363

660

140

350

230

Φ 409

709

160

400

250

Φ 460

756

180

450

275

Φ 520

814

205

500

290

Φ 575

869

225

Seven, pipe requirements:
1, the requirement for straight pipe:
In order to ensure that the instrument, accurate to run normally, sensor must have a certain straight pipe upstream and downstream of the installation points, to adjust the flow field, as shown.

Figure 1: concentric contraction tube;
Figure 2: the concentric expansion tube;
Figure 3: a 90 - degree Angle;
Figure 4: the same plane of two 90 - degree Angle;
Figure 5: different plane of two 90 - degree Angle;
Figure 6: regulating valve should be installed downstream of the sensor in 5 d to the distance, if the sensor must be installed in the upstream, the sensors should be not less than 50 d upstream, straight pipe section downstream straight pipe section should be not less than 5 d.
2, the requirement of pipe:
A, upstream and downstream piping diameter D and the same as the sensor inner diameter DN, its difference satisfy the following conditions: 0.95 DN D 1.1 or less or less DN.
B, piping shall be concentric with sensor, coaxial degree should be less than 0.05 DN.
C, gasket not protruding into the pipe, the inner diameter slightly larger than sensors.
D, if you want to stop inspection and cleaning the sensor, the by-pass pipe should be set up,As shown in the figure below.

 
3, the requirement of pipe vibration:
Sensors to avoid installed on the strong pipeline vibration, if necessary to install, shock absorption measures must be taken, respectively at the upstream and downstream of sensor 2 d piping fastening device, and vibration-proof pad.
Special note: in the air compressor exit strong vibration, cannot install the sensors, shall be installed after the gas storage.

Eight, the requirements:
1, low maintenance - most of the vortex flowmeter are on the market with induction swirl hole or plug-in measurement, once the impurities embedded in the medium pressure hole or sensing element and the table body, the gap between the signal is weak or unstable.A good design should be not easy to plug part, thereby reducing amount of maintenance.
2, inductive components online replacement - some manufacturer of inductive components and vortex street close 2 for one, seemingly simple design to the actual use of inconvenience.Because once induction part failure, you need to medium to the pipe emptying replacement parts, after pressure relief effect production.Perfect design should be separated the two, so can replace the induction part alone, without emptying the media.
3, vortex flowmeter is vulnerable to vibration interference, well-designed vortex flowmeter can through hardware and digital signal processing to exclude interference, and the stability of the signal is obtained.
4, vortex flow meter before and after the installation of a hassle to very long straight section, some manufacturers can offer within the flowmeter reducing design, greatly reduces the user specifically MenWei vortex flowmeter with the demand of the straight pipe.
Need to pay attention to during the period of nine, debugging, using question:
1, flowmeter, on-site installation, maintenance, must abide by the "explosion-proof gas do not open" warnings, and in the open before turn off the power supply.
2, vortex flow meter used in outdoor, suggestion and side shields.
3, shall not be arbitrarily fixed part loosen the flowmeter.The protection of the pressure sensor.Users in the use of traffic time, should pay attention to the flow pressure overload value of pressure sensor is rated working pressure of 1.5 times (that is, the media zui high pressure of 1.5 times).Selection should be within the prescribed flow range, prevent overspeed operation, in order to obtain the ideal accuracy and ensure the normal service life.(due to pressure test, purging pipes or exhaust overdrive, and turbine operation in the reverse flow meter can cause damage)
4 when put into operation, the vortex street flowmeter, should slowly open valve, prevent damage of instantaneous flow and the turbine.Add lubricant should be according to the sign, the number of refueling depends on temperament clean degree, usually 2 ~ 3 times a year.
5, vortex street flowmeter runtime or alternate internal related parameters are not allowed to open the rear cover, otherwise will affect the normal operation of the meter.
Ten, install and use should be paid attention to in the items:
Vortex street no mechanical moving parts, small size, corrosion resistance, stable performance, can be directly display medium work pressure, temperature, flow rate and volume under standard state, wide range, the advantages of small measurement error, has been widely used in oil and gas well production measurement and gas sales.In years of field application, we think the flowmeter zui suitable for relatively clean dry gas metering, gradually become small and medium-sized gas metering.To guarantee the accuracy of the flowmeter measurement, reduce the measuring error, please note:
1, the selection of reasonable
Don't make the actual zui small flow meter QVmin below the selected through runoff flow range limit.
2, installation is correct
Upstream of the vortex flowmeter should have at least 10 d measuring straight pipe length.Straight pipe inner surface should be smooth, cannot have the steps, more smooth connecting flange weld, flange gasket can't into the pipe.Don't put the wrong installation direction of the flow meter.Tests showed that: all the unreasonable installation, will lead to the flowmeter measurement value is low.
3, away from the source of shocks, or install piers in upstream or downstream flow meter, in order to avoid the influence of the pipeline vibration.Avoid strong magnetic field disturbance to the flow meter chip.
4, temperament is relatively clean
Especially not a gas liquid two phase flow;Temperament is dirty, should clean instant flow meter.
5, and reduce the influence of flow pulsation
It can be installed in front of the flow meter buffer tank, or extended length of straight pipe upstream of the flow meter, computation.
6, timely flowmeter for metrological verification, to ensure accurate and reliable value.
Eleven, selection of points:
Correct selection to ensure that the use of vortex flowmeter is better.Should choose what kind of vortex street flowmeter is based on the current body to determine the physical properties and chemical properties of the medium?Make the size of vortex flowmeter, flow range, lining materials, electrode materials and output current, etc?To be the nature of the flow volume and flow measurement requirements.
1, precision function
Precision grade and function in accordance with the requirements of measurement and choose the instrument using fine grade, cost-effective.Such as for trade settlement, product transfer and energy measurement occasions, should choose high precision grade, such as 1.0, 0.5, or higher level;Used in process control, according to the requirements of control choose not with precision grade;Some just check process flow, without having to do precise control and measurement, can choose lower precision grade, such as 1.5, 2.5, 4.0, and even then you can choose cheap plug-in vortex flowmeter.
2, medium can be measured
Medium velocity and diameter, full scale measurement generally medium, the full flow of vortex flowmeter can measure medium velocity in 0.5-12 m/s within the scope of selection, range is wide.Choose different instrument specifications (diameter) and process piping, the same shall consider whether measuring flow range within the scope of the flow velocity, namely when the pipeline flow rate is low, can not meet the requirement of the flow meter, or under the velocity measurement accuracy of the quasi cannot guarantee, the need to reduce the size instrument, which carry high tube flow velocity, measurement results are satisfied.
3, the selection of vortex flow transmitter
In saturated vapor measurement using VA type piezoelectric vortex flow transmitter, due to the vortex flow meter range wide, therefore, in practice, the measurement of saturated steam flow main consideration shall not be less than the lower limit of vortex flowmeters, that is to say, must satisfy the fluid flow rate shall be not less than 5 m/s.According to the size of the YongQiLiang chooses different caliber of vortex flow transmitter, rather than with the existing technology to choose transmitter diameter pipe size.
The choice of 4 pressure transmitter, pressure compensation
Because of the saturated steam pipe length, pressure fluctuation is bigger, pressure compensation must be used, considering the pressure, temperature and density, the relation between measurement using pressure compensation, because the pipeline saturated steam pressure in the range 0.3 0.7 MPa, pressure transmitter ranges 1 MPa.
5, display instrument selection
Display instrument intelligent flow display, a voltage compensation, the instantaneous flow and cumulative flow integrating function.

Twelve, matters needing attention:

1, special flange and straight pipe welding can't with the sensor.

2, when installation should make the flow of sensor mark the direction of flow and the pipe.

3, before the installation of sensor and the flange must be put away in sealing ring grooves.The location of the pressure and temperature measurement point, pressure downstream of the sensor in 3 ~ 5 dn, temperature measuring points in the downstream of 5 ~ 8 dn.

4, when measuring high temperature medium, do not use heat insulation material to wrap around the sensor link rod.

5, shielded cable to connect the sensor, should as far as possible away from the interference of strong electromagnetic field.Absolutely not allowed with high voltage cable laying, shielded cable to shorten as far as possible, and shall not be volume, in order to reduce stray inductance, length should not exceed 200 m.

6, before installation of sensors, pipeline cleaning must be conducted.Flow after rinse tube impurities, avoid clogging sensor.Measuring liquid pipe must be full of measured liquid, prevent the interference of bubbles.

7, measuring gas pipelines to prevent the interference of reservoir fluid.Replace the probe body under the high temperature and high pressure, it must be safe operation, high temperature protection.After cooling step-down replaceable probe at the bottom of the safety conditions.

Thirteen, standard of flow range profile: unit (m3 / h)

traffic 

The liquid flow range

Gas flow range

Saturated steam flow range

CAL

Small flow

Heavy traffic

Small flow

Heavy traffic

Small flow

Heavy traffic

DN25

0.9

14

8.3

110

13

1500

DN40

2.5

35

26

300

25

4400

DN50

3.3

55

36

480

40

6800

DN80

8

150

90

1300

100

19000

DN100

14

240

140

2000

160

29000

DN150

38

450

290

4100

350

66000

DN200

70

850

620

7500

620

118000

DN250

130

1300

700

12500

970

185000

DN300

180

2000

920

16500

1400

267000

14, selection of coding:

Code name

size

Flow range ㎡/h(In the wei and control)

ZW-LUGB-25

DN25

1 ~ 10(liquid)

25 ~ 60(gas)

Steam flow check specifications,DN300The above recommended plug-in vortex flowmeter

ZW-LUGB-32

DN32

1.5 ~ 18(liquid)

15-150(gas)

ZW-LUGB-40

DN40

2.2 ~ 27(liquid)

22.6 ~ 150(gas)

ZW-LUGB-50

DN50

4 ~ 55(liquid)

35 ~ 350(gas)

ZW-LUGB-80

DN80

9 ~ 135(liquid)

90 ~ 900(gas)

ZW-LUGB-100

DN100

14 ~ 200(liquid)

140 ~ 1400(gas)

ZW-LUGB-150

DN150

32 ~ 480(liquid)

300 ~ 3000(gas)

ZW-LUGB-200

DN200

56-800(liquid)

550 ~ 5500(gas)

Code name

function1

N

No temperature pressure compensation

Y

With temperature compensation

Code name

Output type

F1

4-20mAOutput (two-wire system)

F2

4-20mAOutput (three-wire system)

F3

RS485Communication interface

Code name

Measured medium

J1

liquid

J2

gas

J3

steam

Code name

The connection method

L1

Flange mounted

L2

Flange connection type

Code name

function2

E1

1.0level

E2

1.5level

T1

The normal temperature

T2

The high temperature

T3

steam

P1

1.6MPa

P2

2.5MPa

P3

4.0MPa

W1

internal3.6VThe power supply

W2

DC24VThe power supply

N1

Stainless steel

N2

Carbon steel

N3

Anti-corrosion type

15,Order to choose selection guidelines:

Name and model number of 1, 1), (2) the diameter, flow range, (3) whether or not to bring the attached so that we can correct selection for you, (4) using pressure, (5) the use of medium temperature.

2, if has been selected by design units in the way of vortex street flowmeter types, please press type vortex flowmeter directly order from our sales department.

3, when using occasions is very important, or the environment is complex, please try to provide the design drawings and detailed parameters, by wei experts in our audit checks for you.

After-sales service commitment:

1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.

Browse:
Return To The Top

分享到:

欧美久久综合网_国产区一区二区三区_亚洲乱码精品一二三四区日韩在线 _一区二区三区不卡视频在线观看
亚洲国产成人av在线| 欧美一区免费视频| 欧美激情第一页xxx| 亚洲欧美高清| 欧美精品日韩| 欧美一区二区在线免费播放| 欧美性事免费在线观看| 亚洲免费精彩视频| 国内成+人亚洲+欧美+综合在线| 一区二区三区欧美视频| 在线观看精品视频| 久久国产综合精品| 亚洲摸下面视频| 欧美日韩综合久久| 日韩视频在线永久播放| 亚洲大片在线| 你懂的国产精品| 欧美在线亚洲| 国产一区二区在线免费观看| 性做久久久久久免费观看欧美| 中文欧美日韩| 欧美午夜在线视频| 亚洲一区制服诱惑| 亚洲一区二区三区在线播放| 欧美视频一区二区三区…| 一本大道久久a久久综合婷婷| 最近看过的日韩成人| 蜜桃视频一区| 亚洲免费观看高清完整版在线观看熊| 亚洲大胆人体视频| 欧美国产日本韩| 亚洲无线观看| 午夜久久美女| 依依成人综合视频| 欧美成人亚洲成人| 亚洲日本成人网| 日韩视频一区| 国产精品美女在线观看| 久久精品一本| 最新国产精品拍自在线播放| 亚洲欧洲一区二区三区| 欧美视频免费在线观看| 午夜宅男久久久| 久久国产精品99精品国产| 在线免费观看一区二区三区| 欧美大胆a视频| 香蕉久久久久久久av网站| 久久不射中文字幕| 亚洲美女视频网| 国精品一区二区三区| 欧美日韩在线第一页| 欧美在线视频一区| 99re6热在线精品视频播放速度| 国产精品99久久久久久久vr| 国产综合精品| 国产精品99免费看| 免费高清在线一区| 亚洲欧美在线x视频| 亚洲欧洲一区| 性感少妇一区| 亚洲天堂免费观看| 亚洲欧洲精品一区二区三区| 国产日本欧美一区二区| 欧美性猛交xxxx免费看久久久 | 99国产精品视频免费观看| 国产一二三精品| 欧美午夜精品久久久| 欧美sm视频| 美女91精品| 久久在线精品| 久久免费黄色| 免费成人小视频| 麻豆成人精品| 麻豆成人av| 久久中文在线| 欧美暴力喷水在线| 欧美va亚洲va香蕉在线| 免费在线播放第一区高清av| 久久中文在线| 免费成人性网站| 免费观看成人| 欧美精品在线视频| 欧美日韩伦理在线免费| 欧美日韩mp4| 欧美天堂亚洲电影院在线观看| 欧美日韩免费一区二区三区视频| 欧美日韩国产一中文字不卡| 欧美日韩国产综合新一区| 欧美日韩免费| 国产精品日韩专区| 国产综合自拍| 亚洲国产日韩综合一区| 亚洲欧洲日本国产| 99这里只有久久精品视频| 亚洲视频欧洲视频| 性欧美暴力猛交69hd| 亚洲福利视频在线| 99精品99| 欧美一区二视频| 欧美大片91| 国产精品久久7| 在线播放中文字幕一区| 亚洲美女毛片| 欧美一区二区视频在线| 亚洲人成网站色ww在线| 亚洲免费在线电影| 免费在线视频一区| 欧美亚男人的天堂| 亚洲高清视频的网址| 亚洲一级一区| 一本大道av伊人久久综合| 久久久久成人精品| 欧美视频精品一区| 亚洲国产一区二区在线| 午夜精品福利电影| 亚洲国产精品一区二区第四页av | 国产欧美大片| 亚洲区中文字幕| 欧美中文字幕视频在线观看| 亚洲综合二区| 欧美日韩高清区| 曰韩精品一区二区| 亚洲欧美成人在线| 亚洲男人的天堂在线观看| 欧美片在线播放| 在线看不卡av| 亚洲国产精品传媒在线观看 | 国产精品视频999| 亚洲精品国产拍免费91在线| 亚洲第一网站| 久久久久se| 国产欧美一区二区精品婷婷| 一本久久精品一区二区| 一本到高清视频免费精品| 欧美精品激情| 亚洲国产电影| 日韩亚洲欧美高清| 欧美—级a级欧美特级ar全黄| 亚洲第一福利视频| 日韩视频久久| 欧美日韩三级一区二区| 一区二区精品国产| 亚洲欧美久久久| 国产日韩欧美综合精品| 欧美一区二区视频97| 久久久一区二区| 亚洲高清三级视频| 亚洲特黄一级片| 国产精品人人做人人爽| 久久福利一区| 欧美高清视频在线观看| 99精品国产高清一区二区| 午夜欧美理论片| 伊人久久男人天堂| 一本色道久久综合一区| 国产精品美女主播在线观看纯欲| 午夜日本精品| 欧美精品三级| 欧美在线日韩| 欧美日韩国产一级| 午夜日韩电影| 欧美精品黄色| 欧美在线播放一区| 欧美日韩国产精品| 欧美一区二区视频在线| 欧美日韩免费一区二区三区| 欧美在线亚洲一区| 国产精品乱码| 99视频超级精品| 国产综合久久久久久鬼色| 亚洲午夜久久久久久尤物 | 国产欧美韩日| 在线一区二区三区四区五区| 狠狠入ady亚洲精品| 亚洲一区国产视频| 亚洲精华国产欧美| 久久久久久久性| 亚洲一区二区三区免费视频 | 久久久精品国产免大香伊| 在线一区视频| 欧美成人在线免费视频| 久久精品国产91精品亚洲| 国产精品第13页| 宅男精品视频| 亚洲免费观看| 欧美日韩高清在线观看| 亚洲精品一区二区网址| 激情视频一区| 老司机午夜免费精品视频| 久久国产精品黑丝| 国产一区二区视频在线观看| 欧美一区二区视频免费观看| 在线视频你懂得一区| 欧美日韩免费网站| 亚洲手机视频| 一区二区日韩| 国产精品久久一卡二卡| 亚洲一区二区三区免费视频| 欧美成人亚洲成人| 欧美一二三区精品|